banner

maintenance of chemical magnetic pumps

Home

maintenance of chemical magnetic pumps

  • Daily Maintenance of Magnetic Pumps
    Nov 12, 2024
    Magnetic pumps play an important role in industrial production. To ensure their stable and efficient operation, daily maintenance work needs to be carried out from multiple aspects.   Monitoring of Operating Parameters (1) Flow Monitoring   Flow is a key parameter for measuring the working efficiency of magnetic drive pumps. A flowmeter is used to measure and record the flow of the pump regularly. If there are abnormal changes in the flow, the cause needs to be investigated in a timely manner. For example, if the flow gradually decreases, it may be due to the accumulation of impurities in the impeller from the conveyed medium, affecting the normal delivery of the liquid. At this time, the impeller should be cleaned or the filter at the inlet should be checked for blockage. If there is a sudden drop in flow, it may be that the magnetic coupling has failed, affecting the rotational speed of the impeller, and the coupling needs to be inspected and repaired.   (2) Pressure Inspection   Pay close attention to the magnetic drive pumps's inlet and outlet pressures. High outlet pressure may be due to blockage of the outlet pipeline, such as scale build-up or accumulation of foreign objects in the pipeline. The pipeline should be cleaned in a timely manner. Low outlet pressure may be due to damage to the impeller, poor sealing, or internal leakage. Low inlet pressure may cause cavitation, and the tightness of the inlet pipeline and the patency of the filter need to be checked. Timely detection of problems through pressure changes can effectively avoid further damage to the equipment.   (3) Temperature Monitoring   Regularly detect the temperatures of the magnetic drive pump body, isolation sleeve, and motor. An abnormal increase in the pump body temperature may be due to bearing wear, insufficient lubrication, or increased friction between the impeller and the pump casing. An excessively high temperature of the isolation sleeve may be due to increased friction between the internal magnetic rotor and the isolation sleeve or a failure of the cooling system. An excessively high motor temperature may be due to overload, poor heat dissipation, or an electrical fault. When the temperature exceeds the normal range, the machine must be stopped for inspection to prevent component damage.   Visual Inspection (1) Leakage Inspection   Leakage inspection of magnetic drive pump is of crucial importance. Check the pump body, pipeline connection parts, and possible shaft seal locations. If leakage is found, in the sealing gasket, it may be that the gasket is aged or damaged and needs to be replaced in a timely manner. If there are cracks in the pump body causing leakage, minor cracks can be repaired, while severe ones require consideration of replacing the pump body.   (2) Inspection of Component Condition   Check the integrity of components such as the pump body, impeller, and coupling. The pump body should show no signs of deformation or corrosion. If there is corrosion, corresponding anti-corrosion measures can be taken or replacement can be carried out according to the degree of corrosion. The blades of the impeller should not be worn or broken, otherwise, the performance of the pump will be reduced. The coupling should be checked for looseness and wear to ensure a tight connection and good alignment. If there are problems, adjustments or replacements should be made in a timely manner.   Lubrication Maintenance (1) Lubricating Oil Management   The lubricating oil in the bearing box has a great impact on the normal operation of the magnetic pump. Regularly check the oil level to ensure that it is within the range specified by the oil gauge. If it is too low, the bearings will not be lubricated adequately, and if it is too high, overheating and oil leakage may occur. At the same time, observe the oil quality. If the oil color turns black, there are impurities, or emulsification occurs, the lubricating oil should be replaced in a timely manner. Generally, it is replaced every 1,000 - 2,000 hours of operation. When replacing, the bearing box should be thoroughly cleaned.   (2) Grease Replenishment (if applicable)   For parts lubricated with grease, regularly check the remaining amount of grease. When the grease is insufficient, replenish it according to the regulations, taking care to avoid mixing in impurities to ensure the lubrication effect.   Maintenance of Key Components (1) Maintenance of Magnetic Coupling   The magnetic coupling is the core component of the magnetic pump. Regularly check its magnetic strength and coupling condition. This can be judged by observing the operating state of the pump, such as whether the rotational speed is stable and whether there are abnormal vibrations. If a decrease in magnetic strength or decoupling phenomenon is found, it may be that the magnets are damaged or aged, the magnetic coupling components need to be replaced, and the installation gap should be ensured to be correct.   (2) Inspection of Isolation Sleeve   The condition of the isolation sleeve is directly related to the safety of the magnetic pump. Check whether the isolation sleeve is worn, corroded, or cracked. Slight wear can be observed for the time being, but if the wear is severe or there are cracks, it must be replaced immediately to prevent the medium from leaking into the magnetic drive part. Cleaning and Environmental Maintenance (1) Pump Body Cleaning   Keep the surface of the pump body clean. Regularly wipe it with a clean cloth to remove dust, oil, and other substances to prevent impurities from entering the pump and affecting its operation.   (2) Environmental Maintenance   Keep the operating environment of the magnetic pump dry and well-ventilated, and avoid dampness, corrosive gases, etc. from causing damage to the pump body and electrical components.   Electrical System Maintenance (1) Motor Inspection   Check whether the motor wiring is firm and the insulation is good. Regularly measure the insulation resistance of the motor to prevent electric leakage. At the same time, check the heat dissipation situation of the motor to ensure its normal heat dissipation.   (2) Circuit Inspection   Check the start-stop control circuit and protection devices of the magnetic pump to ensure that the control elements work normally and the protection devices function properly to ensure the safe operation of the magnetic pump.   Through the above comprehensive daily maintenance measures, the performance and service life of the magnetic pump can be effectively guaranteed, providing strong support for the stable progress of industrial production. Changyupump is a professional industrial chemical pump manufacturer, get more products from us quickly! Email:jade@changyupump.com  
    Read More

leave a message

leave a message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Submit

Our hours

Mon 11/21 - Wed 11/23: 9 AM - 8 PM
Thu 11/24: closed - Happy Thanksgiving!
Fri 11/25: 8 AM - 10 PM
Sat 11/26 - Sun 11/27: 10 AM - 9 PM
(all hours are Eastern Time)

Contact Us:jade@changyupump.com

Home

Products

whatsApp

contact