{"id":4493,"date":"2026-04-18T11:48:32","date_gmt":"2026-04-18T11:48:32","guid":{"rendered":"https:\/\/changyupump.com\/?p=4493"},"modified":"2026-04-18T11:49:53","modified_gmt":"2026-04-18T11:49:53","slug":"top-5-fluorine-lined-pumps-for-corrosive-chemical-applications","status":"publish","type":"post","link":"https:\/\/changyupump.com\/vi\/blog\/top-5-fluorine-lined-pumps-for-corrosive-chemical-applications\/","title":{"rendered":"Top 5 Fluorine Lined Pumps for Corrosive Chemical Applications"},"content":{"rendered":"\n<p><strong>Fluorine lined pump<\/strong>&nbsp;solutions are essential for safely handling strong acids, alkalis, solvents, and other aggressive fluids. Designed with a corrosion-resistant fluoroplastic lining inside a metal body, these pumps are widely used in chemical processing, electroplating, wastewater treatment, pharmaceutical, and semiconductor industries.<\/p>\n\n\n\n<p>Choosing the right&nbsp;<strong>fluorine lined pump<\/strong>&nbsp;depends on your specific operating conditions, including chemical type, temperature, flow rate, installation layout, and whether the system requires continuous or intermittent operation. This guide covers five reliable options from Changyu Pump, each suited to different industrial scenarios.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"576\" src=\"https:\/\/changyupump.com\/wp-content\/uploads\/2025\/10\/Ultra-high-molecular-weight-polyethylene-fluorine-lined-centrifugal-pump_-the-optimal-engineering-solution-for-sodium-chlorate-transportation-1024x576.webp\" alt=\"Fluorine Lined Pumps \" class=\"wp-image-1467\" srcset=\"https:\/\/changyupump.com\/wp-content\/uploads\/2025\/10\/Ultra-high-molecular-weight-polyethylene-fluorine-lined-centrifugal-pump_-the-optimal-engineering-solution-for-sodium-chlorate-transportation-1024x576.webp 1024w, https:\/\/changyupump.com\/wp-content\/uploads\/2025\/10\/Ultra-high-molecular-weight-polyethylene-fluorine-lined-centrifugal-pump_-the-optimal-engineering-solution-for-sodium-chlorate-transportation-300x169.webp 300w, https:\/\/changyupump.com\/wp-content\/uploads\/2025\/10\/Ultra-high-molecular-weight-polyethylene-fluorine-lined-centrifugal-pump_-the-optimal-engineering-solution-for-sodium-chlorate-transportation-768x432.webp 768w, https:\/\/changyupump.com\/wp-content\/uploads\/2025\/10\/Ultra-high-molecular-weight-polyethylene-fluorine-lined-centrifugal-pump_-the-optimal-engineering-solution-for-sodium-chlorate-transportation.webp 1140w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"what-is-a-fluorine-lined-pump\">What Is a Fluorine Lined Pump?<\/h2>\n\n\n\n<p><strong>A fluorine lined pump<\/strong> combines the mechanical strength of a metal casing with the chemical resistance of a fluoroplastic lining \u2014 typically <strong>PTFE<\/strong>, <strong>PFA<\/strong>, or <strong>FEP<\/strong>. The lining protects the pump&#8217;s internal components from corrosive media, allowing it to handle acids, alkalis, and solvents across the full pH range (0\u201314).<\/p>\n\n\n\n<p>Common lining materials include:<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Lining Material<\/th><th>Temperature Range<\/th><th>Best For<\/th><\/tr><\/thead><tbody><tr><td><strong>PTFE<\/strong><\/td><td>Up to 260\u00b0C<\/td><td>Strong acids, solvents, ultra-pure media<\/td><\/tr><tr><td><strong>PFA<\/strong><\/td><td>Up to 260\u00b0C<\/td><td>High-purity acid, semiconductor use<\/td><\/tr><tr><td><strong>FEP (F46)<\/strong><\/td><td>Up to 200\u00b0C<\/td><td>Pickling fluid, corrosive acid transfer<\/td><\/tr><tr><td><strong>PVDF<\/strong><\/td><td>Up to 140\u00b0C<\/td><td>Chlor-alkali, electroplating, wastewater<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"top-5-fluorine-lined-pumps-for-corrosive-chemical\">Top 5 Fluorine Lined Pumps for Corrosive Chemical Applications<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"1-fzb-series--fluoroplastic-self-priming-centrifug\">1. <a href=\"https:\/\/changyupump.com\/product\/fzb-fluorine-lined-self-priming-centrifugal-pump\/\" data-type=\"link\" data-id=\"https:\/\/changyupump.com\/product\/fzb-fluorine-lined-self-priming-centrifugal-pump\/\">FZB Series \u2014 Fluoroplastic Self-Priming Centrifugal Pump<\/a><\/h3>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"600\" src=\"https:\/\/changyupump.com\/wp-content\/uploads\/2025\/10\/FZB-Series-Fluoroplastic-Centrifugal-Self-Priming-Pump2.webp\" alt=\"FZB Series Fluoroplastic Centrifugal Self-Priming Pump\" class=\"wp-image-1822\" srcset=\"https:\/\/changyupump.com\/wp-content\/uploads\/2025\/10\/FZB-Series-Fluoroplastic-Centrifugal-Self-Priming-Pump2.webp 800w, https:\/\/changyupump.com\/wp-content\/uploads\/2025\/10\/FZB-Series-Fluoroplastic-Centrifugal-Self-Priming-Pump2-300x225.webp 300w, https:\/\/changyupump.com\/wp-content\/uploads\/2025\/10\/FZB-Series-Fluoroplastic-Centrifugal-Self-Priming-Pump2-768x576.webp 768w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/><\/figure>\n\n\n\n<p>The FZB Series is a <strong>fluorine lined self-priming centrifugal pump<\/strong> designed for applications where the pump is positioned above the liquid source or where intermittent priming is required. It is well suited for transferring corrosive acids, alkalis, and chemical solutions from low-level tanks, drums, or pits without the need for external priming systems.<\/p>\n\n\n\n<p><strong>Key features:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Self-priming design for flexible installation<\/li>\n\n\n\n<li>FEP \/ PFA lining for full pH range corrosion resistance<\/li>\n\n\n\n<li>Suitable for intermittent transfer and portable service<\/li>\n\n\n\n<li>Handles most inorganic and organic acids<\/li>\n<\/ul>\n\n\n\n<p><strong>Typical applications:<\/strong>&nbsp;Chemical dosing, acid transfer from drums, wastewater handling, portable field service<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Model<\/th><th>Flow (m\u00b3\/h)<\/th><th>Head (m)<\/th><th>Motor Power (KW)<\/th><th>Speed (r\/min)<\/th><th>Self-priming Height(m)<\/th><th>Self-priming Time (s)<\/th><th>Efficiency (%)<\/th><th>NPSHr(m)<\/th><th>Inlet<\/th><th>Outlet<\/th><\/tr><\/thead><tbody><tr><td>25FZB-20LP<\/td><td>1.5-6<\/td><td>16-19<\/td><td>2.2<\/td><td>2900<\/td><td>0.7<\/td><td>180<\/td><td>10-25<\/td><td>3<\/td><td>25<\/td><td>25<\/td><\/tr><tr><td>40FZB-20P<\/td><td>5-12<\/td><td>17-22<\/td><td>3<\/td><td>2900<\/td><td>1<\/td><td>180<\/td><td>35-46<\/td><td>3<\/td><td>40<\/td><td>50<\/td><\/tr><tr><td>40FZB-30L<\/td><td>5-12<\/td><td>28-32<\/td><td>4<\/td><td>2900<\/td><td>3<\/td><td>150<\/td><td>34-48<\/td><td>3.5<\/td><td>40<\/td><td>50<\/td><\/tr><tr><td>50FZB-20P<\/td><td>8-15<\/td><td>17-22<\/td><td>3<\/td><td>2900<\/td><td>1<\/td><td>180<\/td><td>35-42<\/td><td>3<\/td><td>50<\/td><td>50<\/td><\/tr><tr><td>50FZB-30L<\/td><td>8-15<\/td><td>28-32<\/td><td>4<\/td><td>2900<\/td><td>3<\/td><td>150<\/td><td>24-30<\/td><td>3.5<\/td><td>50<\/td><td>50<\/td><\/tr><tr><td>50FZB-45L<\/td><td>8-15<\/td><td>43-47<\/td><td>7.5<\/td><td>2900<\/td><td>3<\/td><td>150<\/td><td>24-35<\/td><td>3.5<\/td><td>50<\/td><td>40<\/td><\/tr><tr><td>50FZB-70L<\/td><td>8-15<\/td><td>68-72<\/td><td>15<\/td><td>2900<\/td><td>3<\/td><td>150<\/td><td>20-26<\/td><td>4<\/td><td>50<\/td><td>32<\/td><\/tr><tr><td>65FZB-30L<\/td><td>15-35<\/td><td>27-32<\/td><td>7.5<\/td><td>2900<\/td><td>3<\/td><td>200<\/td><td>37-42<\/td><td>4<\/td><td>65<\/td><td>50<\/td><\/tr><tr><td>65FZB-45L<\/td><td>15-35<\/td><td>38-47<\/td><td>11<\/td><td>2900<\/td><td>3<\/td><td>180<\/td><td>30-44<\/td><td>4<\/td><td>65<\/td><td>40<\/td><\/tr><tr><td>65FZB-70L<\/td><td>15-35<\/td><td>65-72<\/td><td>22<\/td><td>2900<\/td><td>3<\/td><td>180<\/td><td>30-42<\/td><td>4<\/td><td>65<\/td><td>40<\/td><\/tr><tr><td>80FZB-30L<\/td><td>35-60<\/td><td>28-35<\/td><td>11<\/td><td>2900<\/td><td>3.5<\/td><td>180<\/td><td>51-63<\/td><td>4.5<\/td><td>80<\/td><td>65<\/td><\/tr><tr><td>80FZB-45L<\/td><td>35-60<\/td><td>42-47<\/td><td>15<\/td><td>2900<\/td><td>3.5<\/td><td>200<\/td><td>45-53<\/td><td>4.5<\/td><td>80<\/td><td>65<\/td><\/tr><tr><td>80FZB-70L<\/td><td>35-60<\/td><td>65-72<\/td><td>30<\/td><td>2900<\/td><td>3.5<\/td><td>250<\/td><td>43-50<\/td><td>5<\/td><td>80<\/td><td>50<\/td><\/tr><tr><td>100FZB-30L<\/td><td>65-110<\/td><td>28-32<\/td><td>18.5<\/td><td>2900<\/td><td>3.5<\/td><td>200<\/td><td>56-80<\/td><td>6<\/td><td>100<\/td><td>80<\/td><\/tr><tr><td>100FZB-45L<\/td><td>65-110<\/td><td>40-46<\/td><td>30<\/td><td>2900<\/td><td>4<\/td><td>250<\/td><td>48-55<\/td><td>6<\/td><td>100<\/td><td>80<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe loading=\"lazy\" title=\"Self priming pump product introduction\" width=\"720\" height=\"405\" src=\"https:\/\/www.youtube.com\/embed\/Q4BupbaNQ3A?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"2-cyl-series--fluorine-lined-vertical-centrifugal\">2. <a href=\"https:\/\/changyupump.com\/product\/fluorine-lined-vertical-centrifugal-pipeline-pumps\/\" data-type=\"link\" data-id=\"https:\/\/changyupump.com\/product\/fluorine-lined-vertical-centrifugal-pipeline-pumps\/\">CYL Series \u2014 Fluorine Lined Vertical Centrifugal Pipeline Pump<\/a><\/h3>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"600\" src=\"https:\/\/changyupump.com\/wp-content\/uploads\/2025\/10\/CYL-Series-Vertical-Inline-Centrifugal-Pump.webp\" alt=\"CYL Series Vertical Inline Centrifugal Pump\" class=\"wp-image-2405\" srcset=\"https:\/\/changyupump.com\/wp-content\/uploads\/2025\/10\/CYL-Series-Vertical-Inline-Centrifugal-Pump.webp 800w, https:\/\/changyupump.com\/wp-content\/uploads\/2025\/10\/CYL-Series-Vertical-Inline-Centrifugal-Pump-300x225.webp 300w, https:\/\/changyupump.com\/wp-content\/uploads\/2025\/10\/CYL-Series-Vertical-Inline-Centrifugal-Pump-768x576.webp 768w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/><figcaption class=\"wp-element-caption\">CYL Series Vertical Inline Centrifugal Pump<\/figcaption><\/figure>\n\n\n\n<p>The CYL Series is a vertical inline centrifugal pump with fluoroplastic lining, designed for compact pipeline installations where floor space is limited. Its vertical structure allows direct inline mounting, making it a practical choice for circulating corrosive fluids in tight process layouts.<\/p>\n\n\n\n<p><strong>Key features:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Inline vertical installation saves footprint<\/li>\n\n\n\n<li>F46 (FEP) or PFA lining for strong acid and alkali resistance<\/li>\n\n\n\n<li>Stable continuous circulation performance<\/li>\n\n\n\n<li>Easy to install and maintain in pipeline systems<\/li>\n<\/ul>\n\n\n\n<p><strong>Typical applications:<\/strong>&nbsp;Acid circulation loops, chemical processing pipelines, electroplating rinse lines, inline transfer systems<\/p>\n\n\n\n<div data-wp-interactive=\"core\/file\" class=\"wp-block-file\"><object data-wp-bind--hidden=\"!state.hasPdfPreview\" hidden class=\"wp-block-file__embed\" data=\"https:\/\/changyupump.com\/wp-content\/uploads\/2025\/10\/CYL-Series-Specifications-1.pdf\" type=\"application\/pdf\" style=\"width:100%;height:600px\" aria-label=\"Nh\u00fang file CYL Series Specifications.\"><\/object><a id=\"wp-block-file--media-07342e00-ae1f-4036-b924-79e814e1bf4f\" href=\"https:\/\/changyupump.com\/wp-content\/uploads\/2025\/10\/CYL-Series-Specifications-1.pdf\">CYL Series Specifications<\/a><a href=\"https:\/\/changyupump.com\/wp-content\/uploads\/2025\/10\/CYL-Series-Specifications-1.pdf\" class=\"wp-block-file__button wp-element-button\" download aria-describedby=\"wp-block-file--media-07342e00-ae1f-4036-b924-79e814e1bf4f\">Download<\/a><\/div>\n\n\n\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe loading=\"lazy\" title=\"CYL series vertical water pumps\" width=\"720\" height=\"405\" src=\"https:\/\/www.youtube.com\/embed\/WKTUKA5DlfY?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"3-cyf-series--fluoroplastic-centrifugal-pump\">3. <a href=\"https:\/\/changyupump.com\/product\/cyf-series-fluoroplastic-centrifugal-pump\/\" data-type=\"link\" data-id=\"https:\/\/changyupump.com\/product\/cyf-series-fluoroplastic-centrifugal-pump\/\">CYF Series \u2014 Fluoroplastic Centrifugal Pump<\/a><\/h3>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"600\" src=\"https:\/\/changyupump.com\/wp-content\/uploads\/2025\/10\/CYF-Series-Fluoroplastic-Centrifugal-Pump-1.webp\" alt=\"CYF Series Fluoroplastic Centrifugal Pump\" class=\"wp-image-1795\" srcset=\"https:\/\/changyupump.com\/wp-content\/uploads\/2025\/10\/CYF-Series-Fluoroplastic-Centrifugal-Pump-1.webp 800w, https:\/\/changyupump.com\/wp-content\/uploads\/2025\/10\/CYF-Series-Fluoroplastic-Centrifugal-Pump-1-300x225.webp 300w, https:\/\/changyupump.com\/wp-content\/uploads\/2025\/10\/CYF-Series-Fluoroplastic-Centrifugal-Pump-1-768x576.webp 768w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/><\/figure>\n\n\n\n<p>The CYF Series is one of <strong>Changyu Pump<\/strong>&#8216;s core fluoroplastic centrifugal pumps, suitable for transferring most corrosive acid and alkali media. With F46 (FEP) or PFA lined wetted parts, it handles a wide range of chemical environments and delivers stable, continuous flow performance.<\/p>\n\n\n\n<p><strong>Key features:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>FEP or PFA lining covers pH 0\u201314<\/li>\n\n\n\n<li>Reliable for most inorganic acids, organic acids, and alkalis<\/li>\n\n\n\n<li>Suitable for continuous transfer in chemical plants<\/li>\n\n\n\n<li>Not recommended for high-temperature conditions or media containing hard particles<\/li>\n<\/ul>\n\n\n\n<p><strong>Typical applications:<\/strong>&nbsp;Sulfuric acid transfer, hydrochloric acid circulation, chemical plant feed lines, waste acid discharge<\/p>\n\n\n\n<div data-wp-interactive=\"core\/file\" class=\"wp-block-file\"><object data-wp-bind--hidden=\"!state.hasPdfPreview\" hidden class=\"wp-block-file__embed\" data=\"https:\/\/changyupump.com\/wp-content\/uploads\/2025\/10\/CYF-Series-Specifications-2.pdf\" type=\"application\/pdf\" style=\"width:100%;height:600px\" aria-label=\"Nh\u00fang file CYF Series Specifications.\"><\/object><a id=\"wp-block-file--media-51b3d06c-a66b-465d-b13f-80c7191e6886\" href=\"https:\/\/changyupump.com\/wp-content\/uploads\/2025\/10\/CYF-Series-Specifications-2.pdf\">CYF Series Specifications<\/a><a href=\"https:\/\/changyupump.com\/wp-content\/uploads\/2025\/10\/CYF-Series-Specifications-2.pdf\" class=\"wp-block-file__button wp-element-button\" download aria-describedby=\"wp-block-file--media-51b3d06c-a66b-465d-b13f-80c7191e6886\">Download<\/a><\/div>\n\n\n\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe loading=\"lazy\" title=\"CYF Fluorine-lined Centrifugal Pump Product Introduction\" width=\"720\" height=\"405\" src=\"https:\/\/www.youtube.com\/embed\/33MTf_QbR_4?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"4-cyq-series--fluoroplastic-magnetic-drive-centrif\">4. <a href=\"https:\/\/changyupump.com\/product\/cyq-sulfuric-acid-magnetic-drive-centrifugal-pump\/\" data-type=\"link\" data-id=\"https:\/\/changyupump.com\/product\/cyq-sulfuric-acid-magnetic-drive-centrifugal-pump\/\">CYQ Series \u2014 Fluoroplastic Magnetic Drive Centrifugal Pump<\/a><\/h3>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"600\" src=\"https:\/\/changyupump.com\/wp-content\/uploads\/2025\/10\/CYQ-Series-Hydrogen-Peroxide-Transfer-Pump-2.webp\" alt=\"CYQ Series Hydrogen Peroxide Transfer Pump\" class=\"wp-image-1816\" srcset=\"https:\/\/changyupump.com\/wp-content\/uploads\/2025\/10\/CYQ-Series-Hydrogen-Peroxide-Transfer-Pump-2.webp 800w, https:\/\/changyupump.com\/wp-content\/uploads\/2025\/10\/CYQ-Series-Hydrogen-Peroxide-Transfer-Pump-2-300x225.webp 300w, https:\/\/changyupump.com\/wp-content\/uploads\/2025\/10\/CYQ-Series-Hydrogen-Peroxide-Transfer-Pump-2-768x576.webp 768w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/><\/figure>\n\n\n\n<p>The CYQ Series is a fluoroplastic magnetic drive pump with a fully sealless design. It uses a magnetic coupling to transmit torque without a shaft penetrating the pump casing, achieving zero leakage. This makes it the preferred choice for toxic, hazardous, flammable, or high-value media where any leakage risk is unacceptable.<\/p>\n\n\n\n<p><strong>Key features:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Sealless magnetic drive \u2014 zero leakage<\/li>\n\n\n\n<li>PTFE, PFA, or FEP wetted materials for full corrosion resistance<\/li>\n\n\n\n<li>No mechanical seal wear, reduced maintenance<\/li>\n\n\n\n<li>Not suitable for media containing hard particles or magnetic metal particles<\/li>\n<\/ul>\n\n\n\n<p><strong>Typical applications:<\/strong>&nbsp;Sulfuric acid, hydrofluoric acid, fuming nitric acid, toxic chemical transfer, semiconductor acid supply, pharmaceutical chemical handling<\/p>\n\n\n\n<div data-wp-interactive=\"core\/file\" class=\"wp-block-file\"><object data-wp-bind--hidden=\"!state.hasPdfPreview\" hidden class=\"wp-block-file__embed\" data=\"https:\/\/changyupump.com\/wp-content\/uploads\/2025\/10\/CYQ-Series-Specifications.pdf\" type=\"application\/pdf\" style=\"width:100%;height:600px\" aria-label=\"Nh\u00fang file CYQ Series Specifications.\"><\/object><a id=\"wp-block-file--media-d188e5a7-26dd-4357-8579-671d220bafd0\" href=\"https:\/\/changyupump.com\/wp-content\/uploads\/2025\/10\/CYQ-Series-Specifications.pdf\">CYQ Series Specifications<\/a><a href=\"https:\/\/changyupump.com\/wp-content\/uploads\/2025\/10\/CYQ-Series-Specifications.pdf\" class=\"wp-block-file__button wp-element-button\" download aria-describedby=\"wp-block-file--media-d188e5a7-26dd-4357-8579-671d220bafd0\">Download<\/a><\/div>\n\n\n\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe loading=\"lazy\" title=\"CYQ series fluoroplastic magnetic pump\" width=\"720\" height=\"405\" src=\"https:\/\/www.youtube.com\/embed\/IyZoRdq51jw?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"5-fyh-series--fluoroplastic-submersible-pump\">5. <a href=\"https:\/\/changyupump.com\/product\/fluoroplastic-submersible-pump\/\" data-type=\"link\" data-id=\"https:\/\/changyupump.com\/product\/fluoroplastic-submersible-pump\/\">FYH Series \u2014 Fluoroplastic Submersible Pump<\/a><\/h3>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"600\" src=\"https:\/\/changyupump.com\/wp-content\/uploads\/2025\/10\/FYH-Series-Fluoroplastic-Submersible-Pump2.webp\" alt=\"FYH Series Fluoroplastic Submersible Pump\" class=\"wp-image-1819\" srcset=\"https:\/\/changyupump.com\/wp-content\/uploads\/2025\/10\/FYH-Series-Fluoroplastic-Submersible-Pump2.webp 800w, https:\/\/changyupump.com\/wp-content\/uploads\/2025\/10\/FYH-Series-Fluoroplastic-Submersible-Pump2-300x225.webp 300w, https:\/\/changyupump.com\/wp-content\/uploads\/2025\/10\/FYH-Series-Fluoroplastic-Submersible-Pump2-768x576.webp 768w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/><\/figure>\n\n\n\n<p>The FYH Series is a <strong>fluoroplastic submersible pump<\/strong> designed for submerged installation directly in corrosive liquid tanks or pits. It is especially useful in low-level tank applications or where above-ground pump installation is not practical. The pump body and impeller use UHMWPE or F46 (FEP) materials for strong corrosion resistance.<\/p>\n\n\n\n<p><strong>Key features:<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Submersible installation for low-level or deep tank use<\/li>\n\n\n\n<li>UHMWPE or FEP wetted parts for acid and alkali resistance<\/li>\n\n\n\n<li>Compact design with no suction piping required<\/li>\n\n\n\n<li>Suitable for scenarios where centrifugal pumps cannot be positioned above the liquid<\/li>\n<\/ul>\n\n\n\n<p><strong>Typical applications:<\/strong>&nbsp;Acid or alkali tank drainage, electroplating bath transfer, wastewater pit pumping, chemical storage tank emptying<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td rowspan=\"2\"><strong>NO<\/strong><\/td><td rowspan=\"2\"><strong>Model<\/strong><\/td><td rowspan=\"2\"><strong>Flow<br>(m\u00b3\/h)<\/strong><\/td><td rowspan=\"2\"><strong>Head<br>(m)<\/strong><\/td><td rowspan=\"2\"><strong>Rev<br>(r\/min)<\/strong><\/td><td colspan=\"2\"><strong>Power<\/strong><\/td><td rowspan=\"2\"><strong>Caliber<br>(mm)<\/strong><\/td><\/tr><tr><td><strong>Axial<br>power<\/strong><\/td><td><strong>Motor<br>power<\/strong><\/td><\/tr><tr><td>1&nbsp;<\/td><td>32FYH-5-20<\/td><td>5&nbsp;<\/td><td>20&nbsp;<\/td><td>2900&nbsp;<\/td><td>0.8&nbsp;<\/td><td>2.2&nbsp;<\/td><td rowspan=\"2\">32\u00d725<\/td><\/tr><tr><td>2&nbsp;<\/td><td>32FYH-10-15<\/td><td>10&nbsp;<\/td><td>15&nbsp;<\/td><td>2900&nbsp;<\/td><td>1.17&nbsp;<\/td><td>2.2&nbsp;<\/td><\/tr><tr><td>3&nbsp;<\/td><td>40FYH-10-20<\/td><td>10&nbsp;<\/td><td>20&nbsp;<\/td><td>2900&nbsp;<\/td><td>1.5&nbsp;<\/td><td>3&nbsp;<\/td><td rowspan=\"2\">40\u00d732<\/td><\/tr><tr><td>4&nbsp;<\/td><td>40FYH-15-20<\/td><td>15&nbsp;<\/td><td>20&nbsp;<\/td><td>2900&nbsp;<\/td><td>2.34&nbsp;<\/td><td>3&nbsp;<\/td><\/tr><tr><td>5&nbsp;<\/td><td>50FYH-10-25<\/td><td>10&nbsp;<\/td><td>25&nbsp;<\/td><td>2900&nbsp;<\/td><td>3.4&nbsp;<\/td><td>4&nbsp;<\/td><td rowspan=\"7\">50\u00d740<\/td><\/tr><tr><td>6&nbsp;<\/td><td>50FYH-10-30<\/td><td>10&nbsp;<\/td><td>30&nbsp;<\/td><td>2900&nbsp;<\/td><td>4.1&nbsp;<\/td><td>5.5&nbsp;<\/td><\/tr><tr><td>7&nbsp;<\/td><td>50FYH-15-30<\/td><td>15&nbsp;<\/td><td>30&nbsp;<\/td><td>2900&nbsp;<\/td><td>5.3&nbsp;<\/td><td>5.5&nbsp;<\/td><\/tr><tr><td>8&nbsp;<\/td><td>50FYH-20-20<\/td><td>20&nbsp;<\/td><td>20&nbsp;<\/td><td>2900&nbsp;<\/td><td>4.6&nbsp;<\/td><td>5.5&nbsp;<\/td><\/tr><tr><td>9&nbsp;<\/td><td>50FYH-20-25<\/td><td>20&nbsp;<\/td><td>25&nbsp;<\/td><td>2900&nbsp;<\/td><td>5.45&nbsp;<\/td><td>5.5&nbsp;<\/td><\/tr><tr><td>10&nbsp;<\/td><td>50FYH-10-40<\/td><td>10&nbsp;<\/td><td>40&nbsp;<\/td><td>2900&nbsp;<\/td><td>6.1&nbsp;<\/td><td>7.5&nbsp;<\/td><\/tr><tr><td>11&nbsp;<\/td><td>50FYH-20-30<\/td><td>20&nbsp;<\/td><td>30&nbsp;<\/td><td>2900&nbsp;<\/td><td>6.54&nbsp;<\/td><td>7.5&nbsp;<\/td><\/tr><tr><td>12&nbsp;<\/td><td>65FYH-25-25<\/td><td>25&nbsp;<\/td><td>25&nbsp;<\/td><td>2900&nbsp;<\/td><td>5.68&nbsp;<\/td><td>7.5&nbsp;<\/td><td rowspan=\"4\">65\u00d750<\/td><\/tr><tr><td>13&nbsp;<\/td><td>65FYH-25-30<\/td><td>25&nbsp;<\/td><td>30&nbsp;<\/td><td>2900&nbsp;<\/td><td>6.8&nbsp;<\/td><td>7.5&nbsp;<\/td><\/tr><tr><td>14&nbsp;<\/td><td>65FYH-30-20<\/td><td>30&nbsp;<\/td><td>20&nbsp;<\/td><td>2900&nbsp;<\/td><td>5.8&nbsp;<\/td><td>7.5&nbsp;<\/td><\/tr><tr><td>15&nbsp;<\/td><td>65FYH-40-20<\/td><td>40&nbsp;<\/td><td>20&nbsp;<\/td><td>2900&nbsp;<\/td><td>6.82&nbsp;<\/td><td>7.5&nbsp;<\/td><\/tr><tr><td>16&nbsp;<\/td><td>65FYH-30-25<\/td><td>30&nbsp;<\/td><td>25&nbsp;<\/td><td>2900&nbsp;<\/td><td>5.84&nbsp;<\/td><td>7.5&nbsp;<\/td><td rowspan=\"6\">65\u00d750<\/td><\/tr><tr><td>17&nbsp;<\/td><td>65FYH-30-30<\/td><td>30&nbsp;<\/td><td>30&nbsp;<\/td><td>2900&nbsp;<\/td><td>6.5&nbsp;<\/td><td>7.5&nbsp;<\/td><\/tr><tr><td>18&nbsp;<\/td><td>65FYH-25-40<\/td><td>25&nbsp;<\/td><td>40&nbsp;<\/td><td>2900&nbsp;<\/td><td>7.79&nbsp;<\/td><td>11&nbsp;<\/td><\/tr><tr><td>19&nbsp;<\/td><td>65FYH-30-40<\/td><td>30&nbsp;<\/td><td>40&nbsp;<\/td><td>2900&nbsp;<\/td><td>9.35&nbsp;<\/td><td>11&nbsp;<\/td><\/tr><tr><td>20&nbsp;<\/td><td>65FYH-35-30<\/td><td>35&nbsp;<\/td><td>30&nbsp;<\/td><td>2900&nbsp;<\/td><td>8.2&nbsp;<\/td><td>11&nbsp;<\/td><\/tr><tr><td>21&nbsp;<\/td><td>65FYH-30-50<\/td><td>30&nbsp;<\/td><td>50&nbsp;<\/td><td>2900&nbsp;<\/td><td>11.7&nbsp;<\/td><td>15&nbsp;<\/td><\/tr><tr><td>22&nbsp;<\/td><td>80FYH-60-15<\/td><td>60&nbsp;<\/td><td>15&nbsp;<\/td><td>2900&nbsp;<\/td><td>6.2&nbsp;<\/td><td>7.5&nbsp;<\/td><td rowspan=\"6\">80\u00d765<\/td><\/tr><tr><td>23&nbsp;<\/td><td>80FYH-60-20<\/td><td>60&nbsp;<\/td><td>20&nbsp;<\/td><td>2900&nbsp;<\/td><td>9.3&nbsp;<\/td><td>11&nbsp;<\/td><\/tr><tr><td>24&nbsp;<\/td><td>80FYH-50-25<\/td><td>50&nbsp;<\/td><td>25&nbsp;<\/td><td>2900&nbsp;<\/td><td>9.7&nbsp;<\/td><td>11&nbsp;<\/td><\/tr><tr><td>25&nbsp;<\/td><td>80FYH-50-30<\/td><td>50&nbsp;<\/td><td>30&nbsp;<\/td><td>2900&nbsp;<\/td><td>10.6&nbsp;<\/td><td>11&nbsp;<\/td><\/tr><tr><td>26&nbsp;<\/td><td>80FYH-40-30<\/td><td>40&nbsp;<\/td><td>30&nbsp;<\/td><td>2900&nbsp;<\/td><td>10.4&nbsp;<\/td><td>11&nbsp;<\/td><\/tr><tr><td>27&nbsp;<\/td><td>80FYH-60-25<\/td><td>60&nbsp;<\/td><td>25&nbsp;<\/td><td>2900&nbsp;<\/td><td>11.5&nbsp;<\/td><td>15&nbsp;<\/td><\/tr><tr><td>28&nbsp;<\/td><td>100FYH-60-30<\/td><td>60&nbsp;<\/td><td>30&nbsp;<\/td><td>2900&nbsp;<\/td><td>14&nbsp;<\/td><td>15&nbsp;<\/td><td rowspan=\"3\">100\u00d780<\/td><\/tr><tr><td>29&nbsp;<\/td><td>100FYH-80-15<\/td><td>80&nbsp;<\/td><td>15&nbsp;<\/td><td>2900&nbsp;<\/td><td>12.8&nbsp;<\/td><td>15&nbsp;<\/td><\/tr><tr><td>30&nbsp;<\/td><td>100FYH-100-10<\/td><td>100&nbsp;<\/td><td>10&nbsp;<\/td><td>2900&nbsp;<\/td><td>13.6&nbsp;<\/td><td>18.5&nbsp;<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe loading=\"lazy\" title=\"FYH series stainless steel semi submersible submers\" width=\"720\" height=\"405\" src=\"https:\/\/www.youtube.com\/embed\/8WVSrquJBak?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"how-to-choose-the-right-fluorine-lined-pump\">How to Choose the Right Fluorine Lined Pump<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><thead><tr><th>Requirement<\/th><th>Recommended Option<\/th><\/tr><\/thead><tbody><tr><td>Sealless, zero leakage for hazardous media<\/td><td>CYQ Series magnetic drive pump<\/td><\/tr><tr><td>Self-priming from low-level tanks or drums<\/td><td>FZB Series self-priming pump<\/td><\/tr><tr><td>Compact inline installation in pipelines<\/td><td>CYL Series vertical pipeline pump<\/td><\/tr><tr><td>Continuous acid\/alkali transfer in chemical plants<\/td><td>CYF Series centrifugal pump<\/td><\/tr><tr><td>Submerged installation in tanks or pits<\/td><td>FYH Series submersible pump<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p>The right pump depends on your chemical type, temperature, flow demand, installation layout, and sealing requirements. Matching pump structure to the actual duty helps improve reliability, reduce maintenance, and extend service life.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"frequently-asked-questions-faq\">Frequently Asked Questions (FAQ)<\/h2>\n\n\n\n<p><strong>Q1: What is the difference between a fluorine lined pump and a full fluoroplastic pump?<\/strong><br><strong>A fluorine lined pump<\/strong> has a metal casing with a fluoroplastic lining inside, combining structural strength with corrosion resistance. A full fluoroplastic pump is made entirely of fluoroplastic, offering higher purity but lower mechanical durability. Fluorine lined pumps are better suited for heavy industrial use.<\/p>\n\n\n\n<p><strong>Q2: Can fluorine lined pumps handle hydrofluoric acid?<\/strong><br>Yes. <strong>PTFE<\/strong> and <strong>PFA lined pumps<\/strong> are resistant to hydrofluoric acid. For toxic media like hydrofluoric acid, a sealless magnetic drive pump such as the CYQ Series is recommended to eliminate any leakage risk.<\/p>\n\n\n\n<p><strong>Q3: Can fluorine lined pumps handle solid particles?<\/strong><br>No. <strong>Fluorine lined centrifugal<\/strong> and <strong>magnetic drive pumps<\/strong> are not suitable for media containing hard solid particles, as particles can damage the lining over time. A slurry pump or UHMWPE-lined pump would be a better choice for particle-laden media.<\/p>\n\n\n\n<p><strong>Q4: How long does a fluorine lined pump typically last?<\/strong><br>Service life depends on the chemical concentration, temperature, and operating frequency. Under normal conditions with compatible media and proper installation, a well-maintained fluorine lined pump can last several years. Avoid dry running and always confirm chemical compatibility before operation.<\/p>\n\n\n\n<p><strong>Q5: Is a fluorine lined pump suitable for high-temperature applications?<\/strong><br>It depends on the lining material. FEP supports up to 200\u00b0C, while PTFE and PFA support up to 260\u00b0C. For applications above 120\u00b0C, PFA lining is recommended. Always verify the temperature rating before selecting.<\/p>\n\n\n\n<p><strong>Q6: Do fluorine lined pumps require special maintenance?<\/strong><br>Routine checks on the mechanical seal, shaft alignment, and lining condition are recommended. Magnetic drive models require less maintenance since there is no mechanical seal to replace. Avoid dry running in all cases, as it can damage the lining and bearings quickly.<\/p>\n\n\n\n<p><strong>Q7: Can I use a fluorine lined pump for both acids and alkalis?<\/strong><br>Yes. PTFE, PFA, and FEP linings cover the full pH range (0\u201314), making fluorine lined pumps suitable for both acid and alkali media. Always verify the specific chemical compatibility, especially at high concentrations or elevated temperatures.<\/p>\n\n\n\n<p><strong>Q8: What certifications or standards should I look for when sourcing a fluorine lined pump?<\/strong><br>Look for pumps that meet ISO, GB (Chinese National Standard), or CE certification. Confirm that the motor protection rating (IP55 as standard) and flange dimensions match your application and regional requirements.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"conclusion\">Conclusion<\/h2>\n\n\n\n<p><strong>Fluorine lined pumps<\/strong> are a practical and reliable solution for handling corrosive chemicals across a wide range of industrial applications. Whether you need sealless magnetic drive performance, self-priming flexibility, compact inline installation, or submerged operation, there is a suitable option for each working condition.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"602\" src=\"https:\/\/changyupump.com\/wp-content\/uploads\/2025\/10\/Changyu-Pump-Factory-1024x602.webp\" alt=\"Changyu Pump Factory\" class=\"wp-image-753\" srcset=\"https:\/\/changyupump.com\/wp-content\/uploads\/2025\/10\/Changyu-Pump-Factory-1024x602.webp 1024w, https:\/\/changyupump.com\/wp-content\/uploads\/2025\/10\/Changyu-Pump-Factory-300x176.webp 300w, https:\/\/changyupump.com\/wp-content\/uploads\/2025\/10\/Changyu-Pump-Factory-768x451.webp 768w, https:\/\/changyupump.com\/wp-content\/uploads\/2025\/10\/Changyu-Pump-Factory-1536x902.webp 1536w, https:\/\/changyupump.com\/wp-content\/uploads\/2025\/10\/Changyu-Pump-Factory.webp 1920w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p>If your application has specific requirements, our professional engineering team can provide a tailored recommendation based on your exact operating conditions.&nbsp;<strong><a href=\"https:\/\/changyupump.com\/contacts\/\">Contact Changyu Pump<\/a> today for expert support.<\/strong><\/p>\n\n\n<style>.kb-form input.kadence-blocks-field.verify{opacity:0.0;position:absolute;top:0.0;left:0.0;width:0.0;height:0.0;z-index:-1;}<\/style>\n<div class=\"wp-block-kadence-form kadence-form-4493_1f1ac0-45 kb-form-wrap\"><form class=\"kb-form\" action=\"\" method=\"post\"><div class=\"kadence-blocks-form-field kb-field-desk-width-100 kb-input-size-standard\"><label for=\"kb_field_4493_1f1ac0-45_0\">Name<\/label><input name=\"kb_field_0\" id=\"kb_field_4493_1f1ac0-45_0\" data-label=\"Name\" type=\"text\" placeholder=\"\" value=\"\" data-type=\"text\" class=\"kb-field kb-text-style-field kb-text-field kb-field-0\"\/><\/div><div class=\"kadence-blocks-form-field kb-form-field-1 kb-field-desk-width-100 kb-input-size-standard\"><label for=\"kb_field_4493_1f1ac0-45_1\">Email<span class=\"required\">*<\/span><\/label><input name=\"kb_field_1\" id=\"kb_field_4493_1f1ac0-45_1\" data-label=\"Email\" type=\"email\" placeholder=\"\" value=\"\" data-type=\"email\" class=\"kb-field kb-text-style-field kb-email-field kb-field-1\" data-required=\"yes\"\/><\/div><div class=\"kadence-blocks-form-field kb-form-field-2 kb-field-desk-width-100 kb-input-size-standard\"><label for=\"kb_field_4493_1f1ac0-45_2\">Message<span class=\"required\">*<\/span><\/label><textarea name=\"kb_field_2\" id=\"kb_field_4493_1f1ac0-45_2\" data-label=\"Message\" type=\"textarea\" placeholder=\"\" data-type=\"textarea\" class=\"kb-field kb-text-style-field kb-textarea-field kb-field-2\" rows=\"4\" data-required=\"yes\"><\/textarea><\/div><input type=\"hidden\" name=\"_kb_form_id\" value=\"4493_1f1ac0-45\"\/><input type=\"hidden\" name=\"_kb_form_post_id\" value=\"4493\"\/><input type=\"hidden\" name=\"action\" value=\"kb_process_ajax_submit\"\/><label class=\"kadence-verify-label\">Email<input class=\"kadence-blocks-field verify\" type=\"text\" name=\"_kb_verify_email\" autocomplete=\"new-password\" aria-hidden=\"true\" placeholder=\"Email\" tabindex=\"-1\" data-1p-ignore=\"true\" data-lpignore=\"true\" \/><\/label><div class=\"kadence-blocks-form-field kb-submit-field kb-field-desk-width-100\"><button class=\"kb-forms-submit button kb-button-size-standard kb-button-width-auto\">Submit<\/button><\/div><\/form><\/div>\n<noscript><div class=\"kadence-blocks-form-message kadence-blocks-form-warning\">Please enable JavaScript in your browser to submit the form<\/div><style>.kadence-form-4493_1f1ac0-45 .kadence-blocks-form-field.kb-submit-field { display: none; }<\/style><\/noscript>\n\n\n<script type=\"application\/ld+json\">\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"FAQPage\",\n  \"mainEntity\": [\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What is the difference between a fluorine lined pump and a full fluoroplastic pump?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"A fluorine lined pump has a metal casing with a fluoroplastic lining inside, combining structural strength with corrosion resistance. A full fluoroplastic pump is made entirely of fluoroplastic, offering higher purity but lower mechanical durability. Fluorine lined pumps are better suited for heavy industrial use.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Can fluorine lined pumps handle hydrofluoric acid?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Yes. PTFE and PFA lined pumps are resistant to hydrofluoric acid. For toxic media like hydrofluoric acid, a sealless magnetic drive pump such as the CYQ Series is recommended to eliminate any leakage risk.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Can fluorine lined pumps handle solid particles?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"No. Fluorine lined centrifugal and magnetic drive pumps are not suitable for media containing hard solid particles, as particles can damage the lining over time. A slurry pump or UHMWPE-lined pump would be a better choice for particle-laden media.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"How long does a fluorine lined pump typically last?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Service life depends on the chemical concentration, temperature, and operating frequency. Under normal conditions with compatible media and proper installation, a well-maintained fluorine lined pump can last several years. Avoid dry running and always confirm chemical compatibility before operation.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Is a fluorine lined pump suitable for high-temperature applications?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"It depends on the lining material. FEP supports up to 200\u00b0C, while PTFE and PFA support up to 260\u00b0C. For applications above 120\u00b0C, PFA lining is recommended. Always verify the temperature rating before selecting.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Do fluorine lined pumps require special maintenance?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Routine checks on the mechanical seal, shaft alignment, and lining condition are recommended. Magnetic drive models require less maintenance since there is no mechanical seal to replace. Avoid dry running in all cases, as it can damage the lining and bearings quickly.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"Can I use a fluorine lined pump for both acids and alkalis?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Yes. PTFE, PFA, and FEP linings cover the full pH range (0\u201314), making fluorine lined pumps suitable for both acid and alkali media. Always verify the specific chemical compatibility, especially at high concentrations or elevated temperatures.\"\n      }\n    },\n    {\n      \"@type\": \"Question\",\n      \"name\": \"What certifications or standards should I look for when sourcing a fluorine lined pump?\",\n      \"acceptedAnswer\": {\n        \"@type\": \"Answer\",\n        \"text\": \"Look for pumps that meet ISO, GB (Chinese National Standard), or CE certification. Confirm that the motor protection rating (IP55 as standard) and flange dimensions match your application and regional requirements.\"\n      }\n    }\n  ]\n}\n<\/script>\n","protected":false},"excerpt":{"rendered":"<p>Fluorine lined pump&nbsp;solutions are essential for safely handling strong acids, alkalis, solvents, and other aggressive fluids. Designed&#8230;<\/p>","protected":false},"author":2,"featured_media":1467,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":""},"categories":[12],"tags":[30,254,46,257,256,255],"class_list":["post-4493","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog","tag-acid-transfer-pump","tag-fluorine-lined-pump-2","tag-fluoroplastic-pump","tag-magnetic-drive-fluorine-pump","tag-pfa-lined-pump","tag-ptfe-lined-pump"],"acf":[],"taxonomy_info":{"category":[{"value":12,"label":"Blog"}],"post_tag":[{"value":30,"label":"Acid Transfer Pump"},{"value":254,"label":"fluorine lined pump"},{"value":46,"label":"Fluoroplastic Pump"},{"value":257,"label":"magnetic drive fluorine pump"},{"value":256,"label":"PFA lined pump"},{"value":255,"label":"PTFE lined pump"}]},"featured_image_src_large":["https:\/\/changyupump.com\/wp-content\/uploads\/2025\/10\/Ultra-high-molecular-weight-polyethylene-fluorine-lined-centrifugal-pump_-the-optimal-engineering-solution-for-sodium-chlorate-transportation-1024x576.webp",1024,576,true],"author_info":{"display_name":"Changyu_","author_link":"https:\/\/changyupump.com\/vi\/author\/changyu_\/"},"comment_info":0,"category_info":[{"term_id":12,"name":"Blog","slug":"blog","term_group":0,"term_taxonomy_id":12,"taxonomy":"category","description":"","parent":0,"count":70,"filter":"raw","cat_ID":12,"category_count":70,"category_description":"","cat_name":"Blog","category_nicename":"blog","category_parent":0}],"tag_info":[{"term_id":30,"name":"Acid Transfer Pump","slug":"acid-transfer-pump","term_group":0,"term_taxonomy_id":30,"taxonomy":"post_tag","description":"","parent":0,"count":11,"filter":"raw"},{"term_id":254,"name":"fluorine lined pump","slug":"fluorine-lined-pump-2","term_group":0,"term_taxonomy_id":254,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw"},{"term_id":46,"name":"Fluoroplastic Pump","slug":"fluoroplastic-pump","term_group":0,"term_taxonomy_id":46,"taxonomy":"post_tag","description":"","parent":0,"count":3,"filter":"raw"},{"term_id":257,"name":"magnetic drive fluorine pump","slug":"magnetic-drive-fluorine-pump","term_group":0,"term_taxonomy_id":257,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw"},{"term_id":256,"name":"PFA lined pump","slug":"pfa-lined-pump","term_group":0,"term_taxonomy_id":256,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw"},{"term_id":255,"name":"PTFE lined pump","slug":"ptfe-lined-pump","term_group":0,"term_taxonomy_id":255,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw"}],"_links":{"self":[{"href":"https:\/\/changyupump.com\/vi\/wp-json\/wp\/v2\/posts\/4493","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/changyupump.com\/vi\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/changyupump.com\/vi\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/changyupump.com\/vi\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/changyupump.com\/vi\/wp-json\/wp\/v2\/comments?post=4493"}],"version-history":[{"count":10,"href":"https:\/\/changyupump.com\/vi\/wp-json\/wp\/v2\/posts\/4493\/revisions"}],"predecessor-version":[{"id":4504,"href":"https:\/\/changyupump.com\/vi\/wp-json\/wp\/v2\/posts\/4493\/revisions\/4504"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/changyupump.com\/vi\/wp-json\/wp\/v2\/media\/1467"}],"wp:attachment":[{"href":"https:\/\/changyupump.com\/vi\/wp-json\/wp\/v2\/media?parent=4493"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/changyupump.com\/vi\/wp-json\/wp\/v2\/categories?post=4493"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/changyupump.com\/vi\/wp-json\/wp\/v2\/tags?post=4493"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}