CQ Series Stainless Steel Magnetic Drive Pump

The CQ Series stainless steel magnetic drive pump replaces dynamic seals with static seals, ensuring the pump’s wetted components remain completely sealed. This design eliminates the leakage, seepage, and dripping issues inherent in mechanical seals found in other pumps. Constructed from stainless steel, this pump offers excellent corrosion resistance and prevents contamination of the conveyed medium.

تشانجيو magnetic drive pumps feature a compact structure, aesthetically pleasing design, small footprint, low noise, reliable operation, and convenient use.

نطاق التدفق :

1.2-60m³/h

نطاق الرأس:

5-50m

الطاقة :

0.12~11Kw

Ambient Temperature:

<40°C, motor temperature rise ≤75°C.

مقدمة

The CQ Series stainless steel magnetic drive pump employs a permanent magnet coupling transmission principle, replacing dynamic seals with static seals to achieve fully sealed, zero-leakage fluid transfer. This completely resolves the leakage issues common in traditional mechanical seal pumps. The pump’s wetted components are manufactured from 304/316L stainless steel (customization available), offering excellent corrosion resistance to ensure pure, contamination-free medium transfer.

This series features a compact structure, small footprint, low noise, and stable, reliable operation. With a flow range of 1.2–60 m³/h and a head of 5–50 m, it is suitable for industries including chemical, pharmaceutical, petroleum, electroplating, food, scientific research, and defense. It safely conveys acidic/alkaline liquids, oils, volatile, and toxic media, and is widely integrated into circulating water systems and filtration equipment.

Structural Diagram of Stainless Steel Magnetic Drive Pump

Continuously Optimized Components: All on Display for You

Structural Diagram of Stainless Steel Magnetic Drive Pump
Structural Diagram of Stainless Steel Magnetic Drive Pump

Stainless Steel Pump Housing

  • Silica sol pickling process, no pinholes or leaks. Available materials: 304, 316L.
  • Flange pressure rating: 0.6MPa. Suitable for media with density below 1.2g/cm³.
  • Cantilevered structure with 5-6mm housing thickness. Newly optimized hydraulic model boosts efficiency by 3%.
Stainless Steel Pump Housing

Monoblock Impeller and Rotor

  • The impeller features front-to-back grinding rings, with flow channels ultrasonically cleaned to remove burrs. The stainless steel surface achieves high polish, enhancing efficiency.
  • Stable bilateral dynamic balancing ensures smoother pump operation.
Monoblock Impeller and Rotor

Stainless Steel Isolation Sleeve

The isolation sleeve is constructed from high-quality stainless steel using laser welding for a seamless, monolithic design. All welds undergo non-destructive testing to ensure uniformity and crack-free integrity. It resists stress deformation during prolonged operation and withstands pressures up to 2 MPa.

Stainless Steel Isolation Sleeve

Powerful Magnet Assembly

  • Advanced push-pull magnetic circuit design. Magnets utilize Grade 12 ferrite permanent magnets, delivering enhanced magnetic torque through the push-pull configuration. Bilateral dynamic balancing and weight reduction ensure smooth operation of the external magnet while minimizing vibration.
  • Surface magnetic flux density: 151 Gauss, non-degradable
  • External magnet dynamic balancing ensures long-term stable operation and extended service life.
  • Ferrite permanent magnets with a maximum temperature rating of 100°C, suitable for conveying media with specific gravity up to 1.2.

Pump Shaft and Bearings

  • High-strength pump shaft design, stainless steel pump shaft, manufactured from solid stainless steel round bar through integral machining for high strength.
    Both ends of the pump shaft are fitted with graphite-filled bearings, utilizing a hard-on-soft pairing to significantly extend service life.
  • Stainless steel main shaft with graphite-filled bearings, suitable for acids, alkalis, salts, and organic solvents.
Pump Shaft and Bearings

Installation Requirements:

  • Magnetic drive pumps should be installed horizontally and should not be mounted vertically. The plastic pump body must not bear the weight of the piping. For special applications requiring vertical installation, the motor must face upward.
  • Pre-startup Inspection:
    • Check that the motor fan blades rotate freely without binding or abnormal noise; ensure all fasteners are secure.
    • Verify that the motor rotation direction matches the magnetic drive pump’s direction indicator.

Operation:

  • After starting the motor, slowly open the discharge valve. Once the pump reaches normal operating conditions, adjust the discharge valve to the required opening. Before stopping the pump, first close the discharge valve, then close the suction pipe valve.
  • Medium Requirements:
    • If the conveyed medium contains solid particles, install a filter screen at the pump inlet. If it contains ferromagnetic particles, install a magnetic filter.
    • The conveyed medium and its temperature must remain within the permissible range for the pump materials.
    • For specific model parameters such as flow rate and power, contact us for a customized solution tailored to your operating conditions.

Operating Conditions

The following restrictions must be strictly adhered to ensure safe operation:

ParameterRequirement
Medium TemperatureStandard Type: ≤100°C; High-Temperature Custom Type: ≤200°C (Requires insulation jacket).
Inlet Pressure≤0.2 MPa. A foot valve is required when the liquid level is below the pump shaft.
Medium CharacteristicsDensity ≤ 1600 kg/m³; Kinematic Viscosity ≤ 30 × 10⁻⁶ m²/s; Must not contain hard solid particles or fibers.
Ambient Temperature< 40°C; Motor temperature rise ≤ 75 K (under rated operating conditions).
Special RequirementsDry running is strictly prohibited (bearings are lubricated by the medium). A filter/strainer is required for media containing solid particles.

المواصفات

Model description

EX:50CQ-32
50 — Pump Rated Head (m)
CQ — Magnetic Drive Pump Designation Code
32 — Pump Inlet Diameter

If you’re unsure which model to choose, please contact us. Our experts will be happy to recommend one for you.

البريد الإلكتروني: jade@changyupump.com

الهاتف +86-13651913727

لا يوجدالطرازالتدفق (متر مكعب/ساعة)الرأس (م)الكفاءة (%)NPSHr (م)مدخل × مخرج (مم)السرعة (ص/دقيقة)قوة المحرك (كيلوواط)الوزن (بالكيلوغرام)
116CQ-5*1.25201.516×1229000.1212
216CQ-8*1.88211.516×1229000.1815
320CQ-12*312212.0 20×1229000.3722
425CQ-15*5.415252.725×2029001.130
532CQ-15*6.515283.0 32×2529001.135
632CQ-25*4.825233.0 32×2529001.135
732CQ-32232202.532×2529002.238
*3.63224
53027
840CQ-206.321203.0 40×3229002.242
*102022
112022
940CQ-326.333243.0 40×322900465
*11.53225
133027
1040CQ-40*6.340213.0 40×322900468
1150CQ-25927303.0 50×402900468
*14.42527
172534
1250CQ-32933283.0 50×402900470
*13.23229
172930
1350CQ-506.350273.0 50×3229005.5108
*7.85028
104733
1465CQ-251526353.0 65×5029004110
*16.82536
202338
1565CQ-321733483.0 65×5029005.5115
*253250
302853
1680CQ-323533483.0 80×65290011155
*503252
602955

التطبيق

Widely applicable in fields requiring the transportation of high-risk, high-purity, or corrosive media:

Industries: Chemical, pharmaceutical, petroleum refining, electroplating, food processing, environmental water treatment, scientific research, and defense industries.

  Medium Types: Acid/alkali solutions, flammable and explosive liquids (e.g., solvents), toxic reagents, valuable pharmaceutical solutions, electroplating solutions, and high-temperature fluids (custom models withstand temperatures ≤200°C).

Highly corrosive chemicals

Chemical

Corrosion-resistant transfer of acids, alkalis, solvents

Pharmaceutical

Clean transfer of high-purity pharmaceutical liquids

Pharmaceutical and fine chemical industries

Scientific Research

Safe transfer of hazardous laboratory chemicals

Food Processing

Food Processing

Hygienic transfer of food-grade and high-purity liquids

Stainless Steel Magnetic Drive Pump Manufacturer

تشانجيو specializes in manufacturing stainless steel magnetic drive pumps for organic solvent and corrosive media transfer. Certified to ISO 9001, with products meeting CE, ATEX, EAC, and API standards, we offer stable quality, fast delivery, and customized solutions to meet diverse operating requirements.

البريد الإلكتروني: jade@changyupump.com

الهاتف +86-13651913727

عرض المصنع

الأسئلة الشائعة

س1: ما الفرق بين المضخة المغناطيسية ومضخة الطرد المركزي؟

A1: تتميز المضخات المغناطيسية ومضخات الطرد المركزي باختلافات كبيرة في مبادئ عملها وتطبيقاتها. تستخدم المضخات المغناطيسية اقترانًا مغناطيسيًا لنقل الطاقة، مما يلغي الحاجة إلى موانع التسرب الميكانيكية التقليدية، مما يؤدي إلى تصميم خالٍ من التسرب ومناسب بشكل خاص لنقل السوائل السامة أو المتطايرة أو المسببة للتآكل. يعزل تصميمها المكونات الداخلية عن البيئة الخارجية، مما يقلل من خطر التسرب ويعزز السلامة. وعلى النقيض من ذلك، تعتمد مضخات الطرد المركزي على دافع دوار لتوليد قوة طرد مركزي، مما يدفع السائل من مركز المضخة إلى الخارج، مما يجعلها مناسبة لنقل السوائل ذات التدفق العالي واللزوجة المنخفضة. ومع ذلك، قد تواجه مخاطر التسرب عند التعامل مع السوائل الخطرة أو السوائل ذات درجة الحرارة العالية. وبشكل عام، تعد المضخات المغناطيسية أكثر ملاءمة للتطبيقات التي تكون فيها سلامة الوسيط أمرًا بالغ الأهمية، في حين أن مضخات الطرد المركزي تستخدم بشكل أكثر شيوعًا لنقل السوائل العامة.

س3: ما هي تطبيقات المضخات المغناطيسية؟

A3: تُستخدم المضخات المغناطيسية على نطاق واسع في مختلف المجالات في المقام الأول بسبب أدائها الممتاز في منع التسرب وسلامتها. في الصناعة الكيميائية، يتم استخدامها في نقل السوائل المسببة للتآكل والسوائل، مما يضمن عدم حدوث أي تسرب عند التعامل مع الوسائط الخطرة. في قطاعي المستحضرات الصيدلانية والصيدلانية الحيوية، تُستخدم المضخات المغناطيسية لنقل الأدوية والسوائل البيولوجية، مما يمنع التلوث التبادلي ويضمن نقاء المنتج. بالإضافة إلى ذلك، تجد تطبيقات في صناعة الأغذية والمشروبات، لا سيما في نقل منتجات الألبان والمشروبات، لضمان النظافة والسلامة. في قطاع حماية البيئة، تُستخدم المضخات المغناطيسية في معالجة مياه الصرف الصحي ومعالجة سوائل النفايات المختلفة. وعموماً، نظراً لكفاءتها وميزات السلامة التي تتميز بها، تلعب المضخات المغناطيسية دوراً حيوياً في تطبيقات نقل السوائل ذات المتطلبات الصارمة.

س5: ما هو مبدأ عمل المضخة المغناطيسية؟

A5: The working principle of a magnetic pump is based on the design of magnetic coupling, which transmits power without the need for traditional mechanical seals. The pump structure typically consists of a drive section and a driven section, where the motor in the drive section generates a rotating magnetic field that drives the internal magnetic coupling to rotate. This magnetic coupling is connected to the pump impeller, allowing the liquid to be drawn in and pushed out through the outlet due to the impeller’s rotation. Throughout this process, the liquid medium isolates the inside of the pump from the outside, preventing any leakage. Since there are no mechanical seals, magnetic pumps are particularly safe for transporting toxic, corrosive, or volatile liquids, while also reducing maintenance needs and extending the lifespan of the equipment. This efficient, leak-free design has led to the widespread use of magnetic pumps in various industrial applications.

س2: ما هي احتياطات استخدام المضخات المغناطيسية؟

A2: When using magnetic pumps, several key considerations should be taken into account to ensure safe and efficient operation. Firstly, it is crucial to always maintain an adequate liquid medium in the pump to prevent dry running, as a lack of liquid can lead to overheating and damage to the components. Additionally, regular checks on the sealing conditions and electrical connections of the pump should be conducted to ensure there are no leaks or poor contacts. The appropriate pump materials should be selected based on the properties of the medium to avoid chemical corrosion and wear. Lastly, during installation and operation, it is important to follow the manufacturer’s guidelines and avoid exceeding the pump’s rated performance to ensure long-term stable operation. By adhering to these precautions, the lifespan of the magnetic pump can be maximized, and its efficiency can be improved.

Q4: Why can’t the magnetic pump run dry?

A4: والسبب الرئيسي في أن المضخات المغناطيسية لا يمكن أن تعمل جافة هو أنها تعتمد على الوسط السائل للتبريد والتشحيم. في ظروف التشغيل العادية، لا يوفر السائل الطاقة فحسب، بل يقلل أيضًا من الاحتكاك وتوليد الحرارة بين المكونات الداخلية للمضخة. إذا كانت المضخة تعمل بدون سائل، يمكن أن تتلف المكونات الداخلية بسبب ارتفاع درجة الحرارة، خاصةً القارنة المغناطيسية والأجزاء الحرجة الأخرى، والتي قد تتعرض للتآكل أو الفشل بشكل كبير. بالإضافة إلى ذلك، يمكن أن يؤدي نقص السائل إلى تلامس الدفاعة مباشرة مع غلاف المضخة، مما يزيد من تفاقم التآكل وربما يؤدي إلى تعطل سريع للمعدات. لذلك، لضمان التشغيل الآمن والفعال للمضخات المغناطيسية، من الضروري تجنب تشغيلها في حالة جافة.

Q6: What are the advantages of CQ Series magnetic pumps in corrosion resistance and maintenance?

A: The CQ Series is made from 304/316L stainless steel for all wetted parts, offering excellent corrosion and wear resistance. Its sealless design eliminates mechanical seal failures, reducing maintenance needs, ensuring long-lasting, reliable, and safe operation even with aggressive chemicals and high-purity media.

زيارة مخصصة

اطلب عرض أسعار مجاني

يُرجى ملء تفاصيل السائل الذي يتم ضخه، بما في ذلك التدفق والرأس والجاذبية النوعية ودرجة الحرارة، حتى نتمكن من التوصية بأفضل مضخة وتقديم عرض أسعار دقيق.

  • حلول المضخات المخصصة حسب الطلب
  • عرض أسعار سريع خلال 24 ساعة
  • المصنع مباشرة وبأسعار تنافسية
  • مهندسون محترفون، استشارات فنية فردية
  • مضخات معتمدة من CE/ISO مع اختبار صارم قبل الشحن
تابعنا: