Top 5 Fluorine Lined Pumps for Corrosive Chemical Applications

Fluorine lined pump solutions are essential for safely handling strong acids, alkalis, solvents, and other aggressive fluids. Designed with a corrosion-resistant fluoroplastic lining inside a metal body, these pumps are widely used in chemical processing, electroplating, wastewater treatment, pharmaceutical, and semiconductor industries.

Choosing the right fluorine lined pump depends on your specific operating conditions, including chemical type, temperature, flow rate, installation layout, and whether the system requires continuous or intermittent operation. This guide covers five reliable options from Changyu Pump, each suited to different industrial scenarios.

Fluorine Lined Pumps

What Is a Fluorine Lined Pump?

A fluorine lined pump combines the mechanical strength of a metal casing with the chemical resistance of a fluoroplastic lining — typically PTFE, PFA, or FEP. The lining protects the pump’s internal components from corrosive media, allowing it to handle acids, alkalis, and solvents across the full pH range (0–14).

Common lining materials include:

Материал подкладкиДиапазон температурЛучшее для
PTFEUp to 260°CStrong acids, solvents, ultra-pure media
PFAUp to 260°CHigh-purity acid, semiconductor use
FEP (F46)Up to 200°CPickling fluid, corrosive acid transfer
PVDFUp to 140°CChlor-alkali, electroplating, wastewater

Top 5 Fluorine Lined Pumps for Corrosive Chemical Applications

1. FZB Series — Fluoroplastic Self-Priming Centrifugal Pump

Центробежный самовсасывающий насос из фторопласта серии FZB

The FZB Series is a fluorine lined self-priming centrifugal pump designed for applications where the pump is positioned above the liquid source or where intermittent priming is required. It is well suited for transferring corrosive acids, alkalis, and chemical solutions from low-level tanks, drums, or pits without the need for external priming systems.

Key features:

  • Self-priming design for flexible installation
  • FEP / PFA lining for full pH range corrosion resistance
  • Suitable for intermittent transfer and portable service
  • Handles most inorganic and organic acids

Типичные области применения: Chemical dosing, acid transfer from drums, wastewater handling, portable field service

МодельРасход (м³/ч)Высота (м)Мощность двигателя (кВт)Скорость (об/мин)Самовсасывающий Высота (м)Время самовсасывания (с)Эффективность (%)NPSHr (м)ВходРозетка
25FZB-20LP1.5-616-192.229000.718010-2532525
40FZB-20P5-1217-2232900118035-4634050
40FZB-30L5-1228-3242900315034-483.54050
50FZB-20P8-1517-2232900118035-4235050
50FZB-30L8-1528-3242900315024-303.55050
50FZB-45L8-1543-477.52900315024-353.55040
50FZB-70L8-1568-72152900315020-2645032
65FZB-30L15-3527-327.52900320037-4246550
65FZB-45L15-3538-47112900318030-4446540
65FZB-70L15-3565-72222900318030-4246540
80FZB-30L35-6028-351129003.518051-634.58065
80FZB-45L35-6042-471529003.520045-534.58065
80FZB-70L35-6065-723029003.525043-5058050
100FZB-30L65-11028-3218.529003.520056-80610080
100FZB-45L65-11040-46302900425048-55610080

2. CYL Series — Fluorine Lined Vertical Centrifugal Pipeline Pump

Вертикальные центробежные насосы серии CYL
Вертикальные центробежные насосы серии CYL

The CYL Series is a vertical inline centrifugal pump with fluoroplastic lining, designed for compact pipeline installations where floor space is limited. Its vertical structure allows direct inline mounting, making it a practical choice for circulating corrosive fluids in tight process layouts.

Key features:

  • Inline vertical installation saves footprint
  • F46 (FEP) or PFA lining for strong acid and alkali resistance
  • Stable continuous circulation performance
  • Easy to install and maintain in pipeline systems

Типичные области применения: Acid circulation loops, chemical processing pipelines, electroplating rinse lines, inline transfer systems

3. CYF Series — Fluoroplastic Centrifugal Pump

Центробежный насос из фторопласта серии CYF

The CYF Series is one of Насос Чанъюй‘s core fluoroplastic centrifugal pumps, suitable for transferring most corrosive acid and alkali media. With F46 (FEP) or PFA lined wetted parts, it handles a wide range of chemical environments and delivers stable, continuous flow performance.

Key features:

  • FEP or PFA lining covers pH 0–14
  • Reliable for most inorganic acids, organic acids, and alkalis
  • Suitable for continuous transfer in chemical plants
  • Not recommended for high-temperature conditions or media containing hard particles

Типичные области применения: Sulfuric acid transfer, hydrochloric acid circulation, chemical plant feed lines, waste acid discharge

4. CYQ Series — Fluoroplastic Magnetic Drive Centrifugal Pump

Насос для перекачки перекиси водорода серии CYQ

The CYQ Series is a fluoroplastic magnetic drive pump with a fully sealless design. It uses a magnetic coupling to transmit torque without a shaft penetrating the pump casing, achieving zero leakage. This makes it the preferred choice for toxic, hazardous, flammable, or high-value media where any leakage risk is unacceptable.

Key features:

  • Sealless magnetic drive — zero leakage
  • PTFE, PFA, or FEP wetted materials for full corrosion resistance
  • No mechanical seal wear, reduced maintenance
  • Not suitable for media containing hard particles or magnetic metal particles

Типичные области применения: Sulfuric acid, hydrofluoric acid, fuming nitric acid, toxic chemical transfer, semiconductor acid supply, pharmaceutical chemical handling

5. FYH Series — Fluoroplastic Submersible Pump

Погружной насос из фторопласта серии FYH

The FYH Series is a фторопластовый погружной насос designed for submerged installation directly in corrosive liquid tanks or pits. It is especially useful in low-level tank applications or where above-ground pump installation is not practical. The pump body and impeller use UHMWPE or F46 (FEP) materials for strong corrosion resistance.

Key features:

  • Submersible installation for low-level or deep tank use
  • UHMWPE or FEP wetted parts for acid and alkali resistance
  • Compact design with no suction piping required
  • Suitable for scenarios where centrifugal pumps cannot be positioned above the liquid

Типичные области применения: Acid or alkali tank drainage, electroplating bath transfer, wastewater pit pumping, chemical storage tank emptying

НЕТМодельПоток
(м³/ч)
Глава
(m)
Rev
(об/мин)
МощностьКалибр
(мм)
Осевой
мощность
Двигатель
мощность
32FYH-5-2020 2900 0.8 2.2 32×25
32FYH-10-1510 15 2900 1.17 2.2 
40FYH-10-2010 20 2900 1.5 40×32
40FYH-15-2015 20 2900 2.34 
50FYH-10-2510 25 2900 3.4 50×40
50FYH-10-3010 30 2900 4.1 5.5 
50FYH-15-3015 30 2900 5.3 5.5 
50FYH-20-2020 20 2900 4.6 5.5 
50FYH-20-2520 25 2900 5.45 5.5 
10 50FYH-10-4010 40 2900 6.1 7.5 
11 50FYH-20-3020 30 2900 6.54 7.5 
12 65FYH-25-2525 25 2900 5.68 7.5 65×50
13 65FYH-25-3025 30 2900 6.8 7.5 
14 65FYH-30-2030 20 2900 5.8 7.5 
15 65FYH-40-2040 20 2900 6.82 7.5 
16 65FYH-30-2530 25 2900 5.84 7.5 65×50
17 65FYH-30-3030 30 2900 6.5 7.5 
18 65FYH-25-4025 40 2900 7.79 11 
19 65FYH-30-4030 40 2900 9.35 11 
20 65FYH-35-3035 30 2900 8.2 11 
21 65FYH-30-5030 50 2900 11.7 15 
22 80FYH-60-1560 15 2900 6.2 7.5 80×65
23 80FYH-60-2060 20 2900 9.3 11 
24 80FYH-50-2550 25 2900 9.7 11 
25 80FYH-50-3050 30 2900 10.6 11 
26 80FYH-40-3040 30 2900 10.4 11 
27 80FYH-60-2560 25 2900 11.5 15 
28 100FYH-60-3060 30 2900 14 15 100×80
29 100FYH-80-1580 15 2900 12.8 15 
30 100FYH-100-10100 10 2900 13.6 18.5 

How to Choose the Right Fluorine Lined Pump

RequirementRecommended Option
Sealless, zero leakage for hazardous mediaCYQ Series magnetic drive pump
Self-priming from low-level tanks or drumsFZB Series self-priming pump
Compact inline installation in pipelinesCYL Series vertical pipeline pump
Continuous acid/alkali transfer in chemical plantsCYF Series centrifugal pump
Submerged installation in tanks or pitsFYH Series submersible pump

The right pump depends on your chemical type, temperature, flow demand, installation layout, and sealing requirements. Matching pump structure to the actual duty helps improve reliability, reduce maintenance, and extend service life.

Frequently Asked Questions (FAQ)

Q1: What is the difference between a fluorine lined pump and a full fluoroplastic pump?
A fluorine lined pump has a metal casing with a fluoroplastic lining inside, combining structural strength with corrosion resistance. A full fluoroplastic pump is made entirely of fluoroplastic, offering higher purity but lower mechanical durability. Fluorine lined pumps are better suited for heavy industrial use.

Q2: Can fluorine lined pumps handle hydrofluoric acid?
Да. PTFE и PFA lined pumps are resistant to hydrofluoric acid. For toxic media like hydrofluoric acid, a sealless magnetic drive pump such as the CYQ Series is recommended to eliminate any leakage risk.

Q3: Can fluorine lined pumps handle solid particles?
Нет. Fluorine lined centrifugal и насосы с магнитным приводом are not suitable for media containing hard solid particles, as particles can damage the lining over time. A slurry pump or UHMWPE-lined pump would be a better choice for particle-laden media.

Q4: How long does a fluorine lined pump typically last?
Service life depends on the chemical concentration, temperature, and operating frequency. Under normal conditions with compatible media and proper installation, a well-maintained fluorine lined pump can last several years. Avoid dry running and always confirm chemical compatibility before operation.

Q5: Is a fluorine lined pump suitable for high-temperature applications?
It depends on the lining material. FEP supports up to 200°C, while PTFE and PFA support up to 260°C. For applications above 120°C, PFA lining is recommended. Always verify the temperature rating before selecting.

Q6: Do fluorine lined pumps require special maintenance?
Routine checks on the mechanical seal, shaft alignment, and lining condition are recommended. Magnetic drive models require less maintenance since there is no mechanical seal to replace. Avoid dry running in all cases, as it can damage the lining and bearings quickly.

Q7: Can I use a fluorine lined pump for both acids and alkalis?
Yes. PTFE, PFA, and FEP linings cover the full pH range (0–14), making fluorine lined pumps suitable for both acid and alkali media. Always verify the specific chemical compatibility, especially at high concentrations or elevated temperatures.

Q8: What certifications or standards should I look for when sourcing a fluorine lined pump?
Look for pumps that meet ISO, GB (Chinese National Standard), or CE certification. Confirm that the motor protection rating (IP55 as standard) and flange dimensions match your application and regional requirements.

Заключение

Fluorine lined pumps are a practical and reliable solution for handling corrosive chemicals across a wide range of industrial applications. Whether you need sealless magnetic drive performance, self-priming flexibility, compact inline installation, or submerged operation, there is a suitable option for each working condition.

Насосный завод Чанъюй

If your application has specific requirements, our professional engineering team can provide a tailored recommendation based on your exact operating conditions. Contact Changyu Pump today for expert support.

Похожие статьи